Challenges and recommendations for magnetic hyperthermia characterization measurements
Resumen: Purpose: The localized heating of magnetic nanoparticles (MNPs) via the application of time-varying magnetic fields–a process known as magnetic field hyperthermia (MFH)–can greatly enhance existing options for cancer treatment; but for broad clinical uptake its optimization, reproducibility and safety must be comprehensively proven. As part of this effort, the quantification of MNP heating–characterized by the specific loss power (SLP), measured in W/g, or by the intrinsic loss power (ILP), in Hm2/kg–is frequently reported. However, in SLP/ILP measurements to date, the apparatus, the analysis techniques and the field conditions used by different researchers have varied greatly, leading to questions as to the reproducibility of the measurements. Materials and Methods: An interlaboratory study (across N = 21 European sites) of calorimetry measurements that constitutes a snapshot of the current state-of-the-art within the MFH community has been undertaken. Identical samples of two stable nanoparticle systems were distributed to all participating laboratories. Raw measurement data as well as the results of in-house analysis techniques were collected along with details of the measurement apparatus used. Raw measurement data was further reanalyzed by universal application of the corrected-slope method to examine relative influences of apparatus and results processing. Results: The data show that although there is very good intralaboratory repeatability, the overall interlaboratory measurement accuracy is poor, with the consolidated ILP data having standard deviations on the mean of ca. ± 30% to ± 40%. There is a strong systematic component to the uncertainties, and a clear rank correlation between the measuring laboratory and the ILP. Both of these are indications of a current lack of normalization in this field. A number of possible sources of systematic uncertainties are identified, and means determined to alleviate or minimize them. However, no single dominant factor was identified, and significant work remains to ascertain and remove the remaining uncertainty sources. Conclusion: We conclude that the study reveals a current lack of harmonization in MFH characterization of MNPs, and highlights the growing need for standardized, quantitative characterization techniques for this emerging medical technology.
Idioma: Inglés
DOI: 10.1080/02656736.2021.1892837
Año: 2021
Publicado en: INTERNATIONAL JOURNAL OF HYPERTHERMIA 38, 1 (2021), 447-460
ISSN: 0265-6736

Factor impacto JCR: 3.753 (2021)
Categ. JCR: RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING rank: 54 / 136 = 0.397 (2021) - Q2 - T2
Categ. JCR: ONCOLOGY rank: 143 / 245 = 0.584 (2021) - Q3 - T2

Factor impacto CITESCORE: 6.0 - Medicine (Q1) - Biochemistry, Genetics and Molecular Biology (Q2)

Factor impacto SCIMAGO: 0.709 - Cancer Research (Q2) - Radiological and Ultrasound Technology (Q2) - Physiology (Q2) - Medicine (miscellaneous) (Q2)

Financiación: info:eu-repo/grantAgreement/EUR/COST-Action/TD1402-Radiomag
Financiación: info:eu-repo/grantAgreement/ES/MINECO/MAT2017-85617-R
Financiación: info:eu-repo/grantAgreement/ES/MINECO/MAT2017-86826-R
Financiación: info:eu-repo/grantAgreement/ES/MINECO/RED2018-102626-T
Financiación: info:eu-repo/grantAgreement/ES/MINECO/SEV-2016-0686
Tipo y forma: Article (Published version)
Área (Departamento): Área Cienc.Mater. Ingen.Metal. (Dpto. Ciencia Tecnol.Mater.Fl.)

Creative Commons You must give appropriate credit, provide a link to the license, and indicate if changes were made. You may do so in any reasonable manner, but not in any way that suggests the licensor endorses you or your use.


Exportado de SIDERAL (2023-05-18-14:52:47)


Visitas y descargas

Este artículo se encuentra en las siguientes colecciones:
Articles



 Record created 2021-05-26, last modified 2023-05-19


Versión publicada:
 PDF
Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)