A Registration-Based Approach to Quantify Flow-Mediated Dilation (Fmd) of the Brachial Artery in Ultrasound Image Sequences
Resumen: Flow-mediated dilation (FMD) offers a mechanism to characterize endothelial function and, therefore, may play a role in the diagnosis of cardiovascular diseases. Computerized analysis techniques are very desirable to give accuracy and objectivity to the measurements. Virtually all methods proposed up to now to measure FMD rely on accurate edge detection of the arterial wall, and they are not always robust in the presence of poor image quality or image artifacts. A novel method for automatic dilation assessment based on a global image analysis strategy is presented. We model interframe arterial dilation as a superposition of a rigid motion and a scaling factor perpendicular to the artery. Rigid motion can be interpreted as a global compensation for patient and probe movements, an aspect that has not been sufficiently studied before. The scaling factor explains arterial dilation. The ultrasound sequence is analyzed in two phases using image registration to recover both transformation models. Temporal continuity in the registration parameters along the sequence is enforced with a Kalman filter since the dilation process is known to be a gradual physiological phenomenon. Comparing automated and gold standard measurements (average of manual measurements) we found a negligible bias (0.05%FMD) and a small standard deviation (SD) of the differences (1.05%FMD). These values are comparable with those obtained from manual measurements (bias = 0.23%FMD, SD(intra-obs) = 1.13%FMD, SD(inter-obs) 1.20%FMD). The proposed method offers also better reproducibility (CV = 0.40%) than the manual measurements (CV = 1.04%).
Idioma: Inglés
DOI: 10.1109/TMI.2003.819278
Año: 2003
Publicado en: IEEE TRANSACTIONS ON MEDICAL IMAGING 22, 11 (2003), 1458-1469
ISSN: 0278-0062

Factor impacto JCR: 3.755 (2003)
Categ. JCR: COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS rank: 4 / 81 = 0.049 (2003) - Q1 - T1
Categ. JCR: ENGINEERING, BIOMEDICAL rank: 3 / 40 = 0.075 (2003) - Q1 - T1
Categ. JCR: RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING rank: 6 / 82 = 0.073 (2003) - Q1 - T1
Categ. JCR: IMAGING SCIENCE & PHOTOGRAPHIC TECHNOLOGY rank: 1 / 13 = 0.077 (2003) - Q1 - T1
Categ. JCR: ENGINEERING, ELECTRICAL & ELECTRONIC rank: 4 / 205 = 0.02 (2003) - Q1 - T1

Tipo y forma: Artículo (Versión definitiva)

Creative Commons Debe reconocer adecuadamente la autoría, proporcionar un enlace a la licencia e indicar si se han realizado cambios. Puede hacerlo de cualquier manera razonable, pero no de una manera que sugiera que tiene el apoyo del licenciador o lo recibe por el uso que hace. No puede utilizar el material para una finalidad comercial. Si remezcla, transforma o crea a partir del material, no puede difundir el material modificado.


Exportado de SIDERAL (2025-01-13-14:28:17)


Visitas y descargas

Este artículo se encuentra en las siguientes colecciones:
Artículos



 Registro creado el 2025-01-13, última modificación el 2025-01-14


Versión publicada:
 PDF
Valore este documento:

Rate this document:
1
2
3
 
(Sin ninguna reseña)