Migration of dihydroxyalkylamines from polypropylene coffee capsules to Tenax® and coffee by salt-assisted liquid–liquid extraction and liquid chromatography–mass spectrometry
Resumen: Migration of N, N-Bis(2-hydroxyethyl) alkyl(C8–C18)amines from five different polypropylene capsules to Tenax® and coffee powder have been studied. A single step extraction-cleanup procedure using salting out liquid–liquid extraction (SALLE) method followed by ultra-high performance liquid chromatography–tandem mass spectrometry (UHPLC–MS/MS) was applied. The critical parameters on the SALLE procedure such as extracting solvent, extracting volume, sample pH, salt and its concentration were optimized. The recovery values were in the range of 87.5%–106.5%. The %RSD were lower than 3.7%. The limit of detection was improved from 2.3 ng/g in Tenax® to 0.8 ng/g in coffee. The results indicated that the analyzed compounds have the potential to migrate from the polypropylene capsule containers to the coffee. In most of the cases, the migrated values were higher in Tenax® than in coffee in a range between 1.8 and 61%. One sample did not comply with the specific migration limit established by the European Commission.
Idioma: Inglés
DOI: 10.1016/j.foodchem.2020.126720
Año: 2020
Publicado en: Food Chemistry 321 (2020), 126720 [7 pp.]
ISSN: 0308-8146

Factor impacto JCR: 7.514 (2020)
Categ. JCR: CHEMISTRY, APPLIED rank: 7 / 74 = 0.095 (2020) - Q1 - T1
Categ. JCR: NUTRITION & DIETETICS rank: 6 / 87 = 0.069 (2020) - Q1 - T1
Categ. JCR: FOOD SCIENCE & TECHNOLOGY rank: 7 / 143 = 0.049 (2020) - Q1 - T1

Factor impacto SCIMAGO: 1.772 - Analytical Chemistry (Q1) - Medicine (miscellaneous) (Q1) - Food Science (Q1)

Financiación: info:eu-repo/grantAgreement/ES/DGA/T53-17R
Tipo y forma: Artículo (PostPrint)
Área (Departamento): Área Química Analítica (Dpto. Química Analítica)
Área (Departamento): Proy. investigación HVA (Dpto. Química Analítica)


Creative Commons Debe reconocer adecuadamente la autoría, proporcionar un enlace a la licencia e indicar si se han realizado cambios. Puede hacerlo de cualquier manera razonable, pero no de una manera que sugiera que tiene el apoyo del licenciador o lo recibe por el uso que hace. No puede utilizar el material para una finalidad comercial. Si remezcla, transforma o crea a partir del material, no puede difundir el material modificado.


Exportado de SIDERAL (2025-11-13-14:57:50)


Visitas y descargas

Este artículo se encuentra en las siguientes colecciones:
Artículos > Artículos por área > Química Analítica



 Registro creado el 2025-11-13, última modificación el 2025-11-13


Postprint:
 PDF
Valore este documento:

Rate this document:
1
2
3
 
(Sin ninguna reseña)