Effects of missing data on heart rate variability metrics

Cajal, Diego (Universidad de Zaragoza) ; Hernando, David ; Lázaro, Jesús (Universidad de Zaragoza) ; Laguna, Pablo (Universidad de Zaragoza) ; Gil, Eduardo (Universidad de Zaragoza) ; Bailón, Raquel (Universidad de Zaragoza)
Effects of missing data on heart rate variability metrics
Resumen: Heart rate variability (HRV) has been studied for decades in clinical environments. Currently, the exponential growth of wearable devices in health monitoring is leading to new challenges that need to be solved. These devices have relatively poor signal quality and are affected by numerous motion artifacts, with data loss being the main stumbling block for their use in HRV analysis. In the present paper, it is shown how data loss affects HRV metrics in the time domain and frequency domain and Poincaré plots. A gap-filling method is proposed and compared to other existing approaches to alleviate these effects, both with simulated (16 subjects) and real (20 subjects) missing data. Two different data loss scenarios have been simulated: (i) scattered missing beats, related to a low signal to noise ratio; and (ii) bursts of missing beats, with the most common due to motion artifacts. In addition, a real database of photoplethysmography-derived pulse detection series provided by Apple Watch during a protocol including relax and stress stages is analyzed. The best correction method and maximum acceptable missing beats are given. Results suggest that correction without gap filling is the best option for the standard deviation of the normal-to-normal intervals (SDNN), root mean square of successive differences (RMSSD) and Poincaré plot metrics in datasets with bursts of missing beats predominance (p<0.05), whereas they benefit from gap-filling approaches in the case of scattered missing beats (p<0.05). Gap-filling approaches are also the best for frequency-domain metrics (p<0.05). The findings of this work are useful for the design of robust HRV applications depending on missing data tolerance and the desired HRV metrics.
Idioma: Inglés
DOI: 10.3390/s22155774
Año: 2022
Publicado en: Sensors 22, 15 (2022), 5774 [22 pp.]
ISSN: 1424-8220

Factor impacto JCR: 3.9 (2022)
Categ. JCR: CHEMISTRY, ANALYTICAL rank: 26 / 86 = 0.302 (2022) - Q2 - T1
Categ. JCR: INSTRUMENTS & INSTRUMENTATION rank: 19 / 63 = 0.302 (2022) - Q2 - T1
Categ. JCR: ENGINEERING, ELECTRICAL & ELECTRONIC rank: 100 / 274 = 0.365 (2022) - Q2 - T2

Factor impacto CITESCORE: 6.8 - Engineering (Q1) - Chemistry (Q1) - Biochemistry, Genetics and Molecular Biology (Q2) - Physics and Astronomy (Q1)

Factor impacto SCIMAGO: 0.764 - Instrumentation (Q1) - Analytical Chemistry (Q1) - Medicine (miscellaneous) (Q2) - Information Systems (Q2) - Biochemistry (Q2) - Atomic and Molecular Physics, and Optics (Q2) - Electrical and Electronic Engineering (Q2)

Financiación: info:eu-repo/grantAgreement/ES/DGA-FSE/T39-20R-BSICoS group
Financiación: info:eu-repo/grantAgreement/ES/MCIU-AEI-FEDER/PID2021-126734OB-C21
Tipo y forma: Artículo (Versión definitiva)
Área (Departamento): Área Ingen.Sistemas y Automát. (Dpto. Informát.Ingenie.Sistms.)
Área (Departamento): Área Teoría Señal y Comunicac. (Dpto. Ingeniería Electrón.Com.)


Creative Commons Debe reconocer adecuadamente la autoría, proporcionar un enlace a la licencia e indicar si se han realizado cambios. Puede hacerlo de cualquier manera razonable, pero no de una manera que sugiera que tiene el apoyo del licenciador o lo recibe por el uso que hace.


Exportado de SIDERAL (2024-03-18-14:56:14)


Visitas y descargas

Este artículo se encuentra en las siguientes colecciones:
Artículos



 Registro creado el 2022-11-24, última modificación el 2024-03-19


Versión publicada:
 PDF
Valore este documento:

Rate this document:
1
2
3
 
(Sin ninguna reseña)