Vascular reactivity characterized by PPG-derived pulse wave velocity

Armañac-Julián, Pablo (Universidad de Zaragoza) ; Kontaxis, Spyridon ; Lázaro, Jesús (Universidad de Zaragoza) ; Rapalis, Andrius ; Brazaitis, Marius ; Marozas, Vaidotas ; Laguna, Pablo (Universidad de Zaragoza) ; Bailón, Raquel (Universidad de Zaragoza) ; Gil, Eduardo (Universidad de Zaragoza)
Vascular reactivity characterized by PPG-derived pulse wave velocity
Resumen: Vascular reactivity is the capacity of the blood vessels to adapt under physiological and environmental stimuli. Heat stress causes changes at vascular level affecting pulse wave velocity (PWV), which can be non-invasively obtained using pulse photoplethysmography (PPG). The study aim is to characterize non-invasive and reliable PPG-derived PWV surrogates that are able to assess vascular reactivity, using data from fifteen healthy male volunteers under heat stress conditions. Pulse arrival time (PAT) is a recognized PWV surrogate measure, but our study explores further by including pulse transit time difference (PTTD) and pulse wave decomposition analysis (PDA). Our results indicate a significant linear decrease in PAT and PDA under heat stress, with an approximate 15% reduction compared to the relax phase, closely correlating with heart rate (HR) alterations. This correlation is likely influenced by factors such as the pre-ejection period or stroke volume changes. In contrast, PTTD demonstrates a distinct pattern: it exhibits significant and rapid changes during the initial exposure to heat stress, with an approximate 30% reduction, yet shows minimal intra-stage variations (around 0 ms/min compared to 2.5 ms/min in PAT). This suggests that PTTD, in measuring acute sympathetic activation responses, effectively minimizes the impact of HR-related phenomena that significantly influence PAT and PDA measurements. Our study highlights PTTD as an underexplored yet promising measure for accurately assessing vasoconstriction and vascular reactivity.
Idioma: Inglés
DOI: 10.1016/j.bspc.2025.107641
Año: 2025
Publicado en: Biomedical Signal Processing and Control 105 (2025), 107641 [8 pp.]
ISSN: 1746-8094

Financiación: info:eu-repo/grantAgreement/ES/DGA-FEDER/T39-23R-BSICoS
Financiación: info:eu-repo/grantAgreement/ES/MCIU-AEI-FEDER/PID2021-126734OB-C21
Financiación: info:eu-repo/grantAgreement/EUR/MICINN/TED2021-131106B-I00
Tipo y forma: Artículo (Versión definitiva)
Área (Departamento): Área Ingen.Sistemas y Automát. (Dpto. Informát.Ingenie.Sistms.)
Área (Departamento): Área Teoría Señal y Comunicac. (Dpto. Ingeniería Electrón.Com.)


Creative Commons Debe reconocer adecuadamente la autoría, proporcionar un enlace a la licencia e indicar si se han realizado cambios. Puede hacerlo de cualquier manera razonable, pero no de una manera que sugiera que tiene el apoyo del licenciador o lo recibe por el uso que hace. No puede utilizar el material para una finalidad comercial.


Exportado de SIDERAL (2025-02-14-14:05:04)


Visitas y descargas

Este artículo se encuentra en las siguientes colecciones:
Artículos > Artículos por área > Máster Universitario en Ingeniería de Sistemas y Automática
Artículos > Artículos por área > Teoría de la Señal y Comunicaciones



 Registro creado el 2025-02-14, última modificación el 2025-02-14


Versión publicada:
 PDF
Valore este documento:

Rate this document:
1
2
3
 
(Sin ninguna reseña)